Configuration — TECH FASS APS mini Plus
Everything you can add with this adapter: where it goes in the tree, what you fill in, and what
you can tell it to do.
APS mini Controller
RS485-to-TCP gateway managing one APS mini bus (up to 32 modules).
|
|
| Add it under |
nothing — this is the top of the tree |
| Identified by |
nothing — there is only one |
| Role |
— |
What you fill in
| Setting |
Required |
Default |
Accepted values |
What it does |
| ip_address |
yes |
— |
host name or IP address |
RS485-to-TCP converter IP address or hostname |
| port |
yes |
10001 |
1–65535 |
TCP port of the RS485-to-TCP converter |
APS mini Module
RS485 bus node at address 1-32. Houses RFID reader, relay outputs, digital inputs, and tamper contact.
|
|
| Add it under |
APS mini Controller (up to 32) |
| Identified by |
the address you fill in below |
| Role |
— |
What you fill in
| Setting |
Required |
Default |
Accepted values |
What it does |
| address |
yes |
— |
1–32 |
RS485 bus address 1-32 |
What you can command it to do
| Command |
What happens |
| Open |
Open door momentarily (unsecure strike temporarily) |
| Activate |
Activate output relay or control point |
| Synchronize Access |
Synchronizes current access settings to the device |
| Full Access Synchronization |
Clears stored synchronization state and performs a full re-upload of all access data |
APS mini Reader
Logical RFID/keypad reader embedded in an ApsMiniModule.
|
|
| Add it under |
APS mini Module (up to 2) |
| Identified by |
the direction you fill in below |
| Role |
counts towards anti-passback |
What you fill in
| Setting |
Required |
Default |
Accepted values |
What it does |
| direction |
yes |
— |
ReaderDirection |
Reader direction relative to the controlled door (also the discovery identity; always set by discovery) |
What you can command it to do
| Command |
What happens |
| Enroll Card |
Start card enrollment process on reader |
APS mini Door
Logical door assembly for one APS mini module (relay 1 = strike, door contact sensor, REX input).
|
|
| Add it under |
APS mini Module (up to 1) |
| Identified by |
the one per parent (identity by type) you fill in below |
| Role |
an access point people pass through |
What it must be linked to
| Setting |
Link to |
Required |
What it is for |
| entry_reader |
APS mini Reader |
yes |
Entry-side reader serving this door |
| exit_reader |
APS mini Reader |
optional |
Reader on the way out; can be fitted only when the entry side uses a Wiegand reader |
What you can command it to do
| Command |
What happens |
| Open |
Open door momentarily (unsecure strike temporarily) |
APS mini Output
Relay 2 (AUX/alarm output) on an APS mini module.
|
|
| Add it under |
APS mini Module (up to 1) |
| Identified by |
the one per parent (identity by type) you fill in below |
| Role |
— |
What you can command it to do
| Command |
What happens |
| Activate |
Activate output relay or control point |
Digital input on an APS mini module (door contact, REX, handle contact, or disable line).
|
|
| Add it under |
APS mini Module (up to 3) |
| Identified by |
the port you fill in below |
| Role |
— |
What you fill in
| Setting |
Required |
Default |
Accepted values |
What it does |
| port |
yes |
— |
1–3 |
Physical IO port number 1-3 (stable hardware identity, independent of configured function) |