Configuration — Ademco Galaxy Gxy Smart

Everything you can add with this adapter: where it goes in the tree, what you fill in, and what you can tell it to do.

Galaxy Gxy Smart Panel

Ademco Galaxy Gxy Smart intrusion panel root device

Add it under nothing — this is the top of the tree
Identified by nothing — there is only one
Role —

What you fill in

Setting Required Default Accepted values What it does
ip_address yes — host name or IP address Panel host or IP address
port optional 10001 1–65535 TCP port (default 10001)
password yes — text GXY SMART password (type 98 login), exactly 10 numeric digits (stored as a secret)
remote_password optional 543210 text Remote password (type 41 login), numeric with minimum length 4 (stored as a secret)
response_timeout_seconds optional 20 1–120 Request/response timeout in seconds

Partition

Alarm partition (area) with independent arm/disarm state

Add it under Galaxy Gxy Smart Panel (up to 32)
Identified by nothing — there is only one
Role an access point people pass through

What you fill in

Setting Required Default Accepted values What it does
address yes — text Partition address (A1–D8)

What you can command it to do

Command What happens
Arm Arm security monitoring
Partial Arm Partially arm security monitoring
Force Arm Force arm partition, bypassing open zones
Disarm Disarm security monitoring
Reset Alarm Acknowledge and reset alarm state on a security partition

Zone

Intrusion detection zone (detector, contact, sensor)

Add it under Galaxy Gxy Smart Panel (up to 512), Remote I/O Module (up to 128)
Identified by nothing — there is only one
Role —

What it must be linked to

Setting Link to Required What it is for
partitions Partition (one or more) optional Device references to partitions this zone belongs to

What you fill in

Setting Required Default Accepted values What it does
address yes — 1001–4158 Zone hardware address in Galaxy symbolic format: block1000 + subgroup10 + position (1-8). E.g. 1011-1018, 1021-1028, ..., 4141-4148, 4151-4158.

What you can command it to do

Command What happens
Bypass Temporarily exclude from monitoring
Cancel Bypass Cancel bypass and resume monitoring

Output

Relay output for sirens, lights, or automation

Add it under Galaxy Gxy Smart Panel (up to 64), Remote I/O Module (up to 16)
Identified by nothing — there is only one
Role —

What you fill in

Setting Required Default Accepted values What it does
address yes — a number Galaxy-encoded output address: panel relays <1000, module relays >=1000 (encoding: moduleNo1000 + slotNo10 + outputNo)

What you can command it to do

Command What happens
Activate Activate output relay or control point
Deactivate Deactivate output relay or control point

Card Reader

Card reader for access control hosted directly on the Galaxy panel bus

Add it under Galaxy Gxy Smart Panel (up to 128)
Identified by nothing — there is only one
Role —

What you fill in

Setting Required Default Accepted values What it does
address yes — 1–128 Reader hardware address

Keypad

PIN keypad for partition arm/disarm and access control

Add it under Galaxy Gxy Smart Panel (up to 40)
Identified by nothing — there is only one
Role —

What you fill in

Setting Required Default Accepted values What it does
address yes — 10–49 Keypad hardware address (block x 10 + position 0-9)

Door Control Module

DCM bus module hosting up to 2 access control readers

Add it under Galaxy Gxy Smart Panel (up to 32)
Identified by nothing — there is only one
Role —

What you fill in

Setting Required Default Accepted values What it does
address yes — a number DCM module address: block x 100 + 0 + position 0-7 (e.g. 100..107, 200..207, 300..307, 400..407)

DCM Reader

Access control reader (card + PIN) hosted by a DCM module

Add it under Door Control Module (up to 2)
Identified by nothing — there is only one
Role —

What you fill in

Setting Required Default Accepted values What it does
address yes — 1–2 Reader position within parent DCM (1 or 2)

Remote I/O Module

RIO bus expander module (host for additional zones and outputs)

Add it under Galaxy Gxy Smart Panel (up to 64)
Identified by nothing — there is only one
Role —

What you fill in

Setting Required Default Accepted values What it does
address yes — a number RIO module address: block x 100 + position 0-15 (e.g. 100..115, 200..215, 300..315, 400..415)