Connection, health and audit

Feature Supported Limitation
Connection & session Partially The system has to reach the panel at a known address, so a panel that dials in by itself cannot be used, and the encrypted link cannot be checked against a certificate.
Liveness / keepalive Yes —
Time synchronization Yes —
Offline audit recovery Partially Events recorded while the connection was down are sent by the panel afterwards, but there is no guarantee how far back they reach or that none of them arrives twice.
Health & supervision Yes —
Configuration & reset audit Partially Changes made to the panel settings are recorded, but wiping the panel back to its factory or default state is not recorded as its own audit entry.
Configuration discovery Partially The panel, its expansion modules, inputs, outputs, readers and doors all have to be entered by hand; nothing is read in from the hardware automatically.

Access control

Feature Supported Limitation
Credential management Partially People can be given cards and PIN codes, but fingerprints, phone credentials and cards that stop working after a set number of uses cannot be sent to the panel.
Card formats Partially Cards are recognised only by their full number in one of seven fixed lengths, so the site and card numbers printed on a card cannot be entered separately.
Sync mode Yes —
Reset & restore Yes —
Double-sync safety Partially Sending the same people to the panel a second time is expected to change nothing, but this has not been confirmed on real hardware.
Schedules / time profiles Yes —
Access levels / groups Yes —
Holidays Yes —
Antipassback Yes —
Door control Partially A door can be released for a moment and switched between locked and unlocked, but it cannot be held open permanently and there is no single emergency lockdown.
Reader mode / enable Partially A reader keeps the mode it was given when it was set up; it cannot be switched off or moved to another mode, such as card plus PIN, while the system runs.
Access events Yes —
Enrollment Partially A new card can be registered by presenting it at a reader within a minute, but PIN codes, fingerprints and face data still have to be entered by hand.

Intrusion detection

Feature Supported Limitation
Arm / disarm Partially An area can be armed fully, armed despite open detectors, and disarmed, but partial modes such as guarding only the perimeter while people stay inside are not available.
Bypass Yes —
Alarm reset No — the hardware cannot do it A triggered alarm cannot be cleared from the system; someone has to reset it at the panel or a keypad.
Partitions / zones Yes —
Alarms / tampers / troubles / restores Yes —
User-code management Partially PIN codes reach the panel, but a code that may only arm, or one that silently signals a person is being forced, cannot be set up from the system.
Entry / exit delay Partially Each detection point has its own entry and exit delay time, but the running countdown after someone enters or before an area arms is not shown anywhere.
Sounder / alarm control No — the hardware cannot do it Sirens cannot be silenced, sounded or tested from the system; that has to be done at the panel.

Safety

Feature Supported Limitation
Panic / duress / emergency Partially It is reported when someone enters the code that signals being forced, but panic, medical and evacuation calls are not, and no emergency can be raised from the system.

Inputs and outputs

Feature Supported Limitation
Inputs Yes —
Outputs Yes —
Output schedules No — the hardware cannot do it Outputs and relays can only be switched on and off as they are needed; they cannot be given a timetable that the panel follows on its own.

Manufacturer gateway

Feature Supported Limitation
External lifecycle Yes —
Shared transport Yes —
Platform limits / SDK errors Partially Commands that fail, time out or are refused by the panel are retried and reported, but a dial-in connection and certificate-checked encryption cannot be selected at all.