Configuration — Paradox EVO Intrusion Panel

Everything you can add with this adapter: where it goes in the tree, what you fill in, and what you can tell it to do.

ParadoxPanel

Add it under nothing — this is the top of the tree
Identified by nothing — there is only one
Role —

What you fill in

Setting Required Default Accepted values What it does
ip_address yes — host name or IP address IP150+ module host or IP address
port optional 10000 1–65535 TCP port (default 10000)
response_timeout_seconds optional 20 1–120 Request/response timeout in seconds for panel communication
password yes paradox text IP150+ module password (stored as a secret)
pc_password yes — text Panel PC password (4 digits, 0000 is not allowed by the panel) (stored as a secret)

Paradox EVO48 Panel

Paradox EVO48 intrusion alarm panel (48 zones, 4 partitions)

Add it under nothing — this is the top of the tree
Identified by nothing — there is only one
Role —

Paradox EVO192 Panel

Paradox EVO192 intrusion alarm panel (192 zones, 8 partitions)

Add it under nothing — this is the top of the tree
Identified by nothing — there is only one
Role —

Paradox EVO HD+ Panel

Paradox EVO HD+ intrusion alarm panel (8-192 zones, 8 partitions)

Add it under nothing — this is the top of the tree
Identified by nothing — there is only one
Role —

Partition

Alarm partition (area) with independent arm/disarm state and EVO regular/stay/instant/force arming

Add it under ParadoxPanel (up to 8)
Identified by the address you fill in below
Role an access point people pass through

What you fill in

Setting Required Default Accepted values What it does
address yes — 1–8 Partition number (1-8)

What you can command it to do

Command What happens
Arm Arm security monitoring
Stay Arm Arm perimeter zones only, interior zones remain disarmed
Sleep Arm Arm perimeter and interior zones with reduced entry delay for nighttime
Force Arm Force arm partition, bypassing open zones
Disarm Disarm security monitoring

Zone

Intrusion detection zone (detector, contact, sensor)

Add it under ParadoxPanel (up to 192), Zone Expander (up to 8), Keypad (up to 8), Keypad with Reader (up to 8), ACM-12 (up to 192)
Identified by the address you fill in below
Role —

What it must be linked to

Setting Link to Required What it is for
partitions Partition (one or more) optional Device references to partitions this zone belongs to

What you fill in

Setting Required Default Accepted values What it does
address yes — 1–192 Zone number (1-192)

What you can command it to do

Command What happens
Bypass Temporarily exclude from monitoring
Cancel Bypass Cancel bypass and resume monitoring

Output

PGM relay output for sirens, lights, or automation

Add it under ParadoxPanel (up to 32), ACM-12 (up to 32), Keypad (up to 32), Keypad with Reader (up to 32), Zone Expander (up to 32)
Identified by the address you fill in below
Role —

What you fill in

Setting Required Default Accepted values What it does
address yes — 1–32 PGM output number (1-32)

What you can command it to do

Command What happens
Activate Activate output relay or control point
Deactivate Deactivate output relay or control point

Zone Expander

Zone expansion bus module

Add it under ParadoxPanel (up to 15)
Identified by the address you fill in below
Role —

What you fill in

Setting Required Default Accepted values What it does
address yes — 1–15 Module address on bus
serial_number optional — a number Module serial number

Keypad

Security keypad for user interaction and display

Add it under ParadoxPanel (up to 8)
Identified by the address you fill in below
Role —

What you fill in

Setting Required Default Accepted values What it does
address yes — 1–8 Keypad address on bus

Keypad with Reader

Security keypad with integrated dual card reader

Add it under Door (up to 1), ParadoxPanel (up to 8)
Identified by the address you fill in below
Role counts towards anti-passback

What you fill in

Setting Required Default Accepted values What it does
address yes — 1–8 Keypad address on bus

What you can command it to do

Command What happens
Enroll Card Start card enrollment process on reader

ACM-12

Access control module for door and reader management

Add it under ParadoxPanel (up to 254)
Identified by the address you fill in below
Role —

What you fill in

Setting Required Default Accepted values What it does
address yes — 1–254 Module address on bus
serial_number optional — a number Module serial number

Door

Physical access control door with lock state

Add it under ACM-12 (up to 32), ParadoxPanel (up to 32)
Identified by the address you fill in below
Role an access point people pass through

What you fill in

Setting Required Default Accepted values What it does
address yes — 1–32 Door number (1-32)

What you can command it to do

Command What happens
Open Open door momentarily (unsecure strike temporarily)
Open Permanent Hold door unsecured indefinitely (extended access mode)
Close Close a permanently opened door - return to normal operation

Reader

Card reader for access control

Add it under Door (up to 1)
Identified by the one per parent (identity by type) you fill in below
Role counts towards anti-passback

What you can command it to do

Command What happens
Enroll Card Start card enrollment process on reader