Abbas Dominus3 Security System

Abbas Dominus3 intrusion panel with access control via Outdom2 SDK

Manufacturer Abbas
Integration version 1.0.0
Used for intrusion detection
Connects over the manufacturer's own interface
Finds hardware by itself yes — the panel is read in and what it finds appears in the tree
Sets the hardware clock yes

What can be connected

The tree an installer builds: each arrow shows what is mounted under what, and how many of them one parent takes.

graph TD
    Panel["Dominus3 Panel"]
    Subsystem["Subsystem"]
    Concentrator["Concentrator"]
    Detector["Detector"]
    Keypad["Keypad"]
    PowerSupply["Power Supply"]
    SargosModule["Sargos Distress Module"]
    Relay["Relay Output"]
    AccessModule["Access Module"]
    Channel["Channel"]
    AccessDoor["Access Door"]
    Panel -->|up to 255| Subsystem
    Panel -->|up to 255| Concentrator
    Concentrator -->|up to 255| Detector
    AccessModule -->|up to 255| Detector
    Keypad -->|up to 255| Detector
    Panel -->|up to 255| Keypad
    Panel -->|up to 255| PowerSupply
    Panel -->|up to 255| SargosModule
    Panel -->|up to 255| Relay
    Panel -->|up to 255| AccessModule
    AccessModule -->|up to 2| Channel
    Panel -->|up to 255| AccessDoor

In this guide

Connecting the hardware What to set on the equipment and its converter before PQ can reach it
Configuration Everything you can add, what it needs filled in, and what you can command it to do
What it can do Feature-by-feature, including what this hardware cannot do
Events What appears in the event log, and how serious it is

| Cards and access rights | What is stored in the hardware and how much of it fits |

| Tested behaviour | What was verified on real hardware, and with what result |